Tools
This is a reference catalogue. Tools cannot be configured or run from this page.
Devices restart inference
ROBOFLOW_MCP_DEVICES_RESTART_INFERENCERequest a restart of the device's inference runtime. Interrupts running pipelines. This restarts inference, not the host operating system. Returns ``{id}`` for the queued command, not proof that the restart completed. Follow up with ``devices_get_snapshot`` or ``devices_get_events`` to verify recovery. Offline devices cannot execute commands; undelivered commands expire after 5 minutes. Do not retry automatically, because each call queues another restart.
Devices restart poe port
ROBOFLOW_MCP_DEVICES_RESTART_POE_PORTRequest a power cycle of one camera's PoE port on supported edge hardware. Interrupts the camera and its stream while power is cycled. Choose the interface associated with the affected camera, not an arbitrary network interface. Returns ``{id}`` for the queued command, not a completed reset. Follow up with ``devices_get_events`` and ``devices_streams_get`` to verify recovery. Each call requests a new power cycle; undelivered commands expire after 5 minutes.
Devices send command
ROBOFLOW_MCP_DEVICES_SEND_COMMANDQueue a command on the device's command channel. Requires the ``device:update`` scope. A returned ``id`` means a command was queued for the device's next poll. Stream config commands may instead return ``{id: null, staged: true}``; inspect ``devices_get_config.configProposal`` before claiming a live change. Camera-capture commands (``livesample``, ``trigger_stream``, and ``cloud_fallback`` starts) can return 403 with ``error_type=CAMERA_STREAM_DISABLED`` when workspace, device, or stream settings disable viewing. Other commands, including capture stops, remain available. Queued capture commands are checked again before device delivery, so a later opt-out can prevent execution. For a connectivity check from the device, use ``action='network_probe'`` and ``data`` with ``kind`` (``ping``, ``dns``, ``tcp`` or ``http``) and ``target`` (IP address or hostname up to 253 characters, with labels of at most 63 characters; not a URL or zone-scoped IP). Optional whole-number ``count`` is 1-10 and ``timeout_s`` is 1-15. ``port`` is 1-65535, required for TCP, optional for HTTP, and invalid for ping or DNS. ``scheme`` is ``http`` or ``https`` for HTTP only. Other fields are rejected. The returned ``id`` identifies the queued command, not a completed probe. Results arrive asynchronously in device monitoring under ``network_probes[id]``.
Devices set service version
ROBOFLOW_MCP_DEVICES_SET_SERVICE_VERSIONPin one service's version without replacing the rest of the config. Requires the ``device:update`` scope. Respects the maintenance window and queued changes. Returns ``{success, deferred}``; success means the config was saved, not that the device installed the version.
Devices snooze alerts
ROBOFLOW_MCP_DEVICES_SNOOZE_ALERTSSnooze the device's health alerts for one day. Requires the ``device:update`` scope. Returns ``{deviceId, alerts_snoozed_until}``.
Devices streams capture frame
ROBOFLOW_MCP_DEVICES_STREAMS_CAPTURE_FRAMECapture the stream's latest frame for a project. When the response has ``status="screening"``, the frame is held for an upload screening verdict and is not yet in the project. The returned project details identify the requested destination, not a frame ready to open or use. Otherwise the frame is added to the project. Requires ``device:read`` plus ``image:create`` on a credential not limited to project groups. Workspace, device, or stream privacy restrictions return 403 with ``error_type=CAMERA_STREAM_DISABLED``; other 403 responses can indicate missing upload permission.
Devices streams create
ROBOFLOW_MCP_DEVICES_STREAMS_CREATECreate a stream on a device through the ``add_stream`` command. Requires the ``device:update`` scope. On V2 devices the platform applies this as a config update (``status: "applied"``, no command id) or stages it for production approval (``status: "staged"``). An applied stream shows in ``devices_streams_list`` as ``provisioning`` until the device reports it running. The Workflow may write to external integrations once the stream runs. For a direct Asset Library video stream on a supported edge release, use ``asset://<finalVideoId>`` as video_reference. Poll video_upload_status until ``uploaded`` and take the final videoId from that response, which can change after deduplication. The caller needs image:read and access to that video; the device API key needs image:read and access to its folder. For nearby-claimed runtime keys, use the RTSP Simulator. Direct playback needs network access for its first download, enough disk space, and a video within the device cache limit (1 GiB by default, set by ASSET_VIDEO_CACHE_MAX_BYTES). Use the reference directly in the stream, not in video_sources. RTSP Simulator remains an option.
Devices streams delete
ROBOFLOW_MCP_DEVICES_STREAMS_DELETERemove a stream's state document. Requires the ``device:update`` scope. Remove the stream from the device config too (``devices_update_config``), or the device recreates it.
Devices streams get
ROBOFLOW_MCP_DEVICES_STREAMS_GETGet a single stream by id. Returns the Stream object. Streams that exist only in the device config are returned as synthesized ``provisioning`` entries rather than 404; 404 only if the stream exists neither live nor in config. Includes structured ``error_code``, ``error_message``, and ``error_retryable`` alongside the legacy ``error`` text.
Devices streams list
ROBOFLOW_MCP_DEVICES_STREAMS_LISTList streams configured on the device. Returns a list of Stream objects, including streams that exist only in the device config and have not been reported by the device yet (``status: "provisioning"``, ``provisioning: true``). ``mode`` is ``"triggered"`` for trigger-driven streams, ``"continuous"`` otherwise. Credential-bearing fields (URL userinfo, ``password``, ``credential``, etc.) are redacted from the ``source`` and ``configured_source`` fields. ``id`` is the platform stream record, while ``pipeline_id`` is the runtime pipeline identifier. Use both values from the same object when pausing or resuming. Structured ``error_code``, ``error_message``, and ``error_retryable`` describe the latest status-event failure; null means the field was not reported.
Devices streams pause
ROBOFLOW_MCP_DEVICES_STREAMS_PAUSERequest a pause of a running device stream without removing its config. ``pipeline_id`` targets the edge pipeline. Pass ``stream_id`` from the same Stream object when it is a platform record; omit it for a ``provisioning`` entry, whose id is only the stream name. Returns ``{id}`` for the queued command, not completed execution. Read ``devices_streams_get`` afterward to confirm the status. Undelivered commands expire after 5 minutes.
Devices streams resume
ROBOFLOW_MCP_DEVICES_STREAMS_RESUMERequest that a paused device stream resume processing. ``pipeline_id`` targets the edge pipeline. Pass ``stream_id`` from the same Stream object when it is a platform record; omit it for a ``provisioning`` entry, whose id is only the stream name. Returns ``{id}`` for the queued command, not completed execution. Read ``devices_streams_get`` afterward to confirm the status. Resuming a configured Workflow can execute external actions. Undelivered commands expire after 5 minutes.
Devices streams sample frame
ROBOFLOW_MCP_DEVICES_STREAMS_SAMPLE_FRAMELook at what a device camera sees right now. Returns the frame as an image plus ``image_url``: a signed URL, valid for an hour, that Workflow and model tools accept as an image input. Use it to design a Workflow against the real scene, then run the Workflow on ``image_url`` to check it before deploying to the device. Requires the ``device:update`` scope: when no frame is under 10s old the platform asks the device to start sending preview frames and waits. 504 means the device sent none in time (offline or stalled stream). Workspace, device, or stream privacy restrictions return 403 with ``error_type=CAMERA_STREAM_DISABLED``; other 403 responses can have different permission causes.
Devices streams terminate
ROBOFLOW_MCP_DEVICES_STREAMS_TERMINATERemove a stream from a device permanently. Requires the ``device:update`` scope. On V2 devices the stream is removed from the device config at once (``status: "applied"``), or the removal is held for production approval (``status: "staged"``). Otherwise a ``terminate_stream`` command is queued, and the device targets the pipeline by ``pipeline_id``. To stop processing temporarily use ``devices_streams_pause``. ``devices_streams_delete`` removes only monitoring state, so a configured stream comes back after it.
Devices streams trigger
ROBOFLOW_MCP_DEVICES_STREAMS_TRIGGERRequest one Workflow execution on a trigger-driven device stream. The platform resolves the Workflow and workspace from the stream or device config. Camera capture must be allowed by workspace, device, or stream settings. A privacy refusal returns 403 with ``error_type=CAMERA_STREAM_DISABLED``. Queued capture commands are checked again before delivery, so a later opt-out can prevent execution. The Workflow may write to external integrations, so do not retry automatically. Returns ``{id}`` for the queued command, not inference output or proof of completion. Follow up with ``devices_get_events`` and ``devices_streams_get`` for status. Undelivered commands expire after 5 minutes.
Devices streams update
ROBOFLOW_MCP_DEVICES_STREAMS_UPDATEMerge fields into a stream's ``data`` map. Requires the ``device:update`` scope. To change what the stream runs, edit ``stream`` in the device config with ``devices_update_config``.
Devices update
ROBOFLOW_MCP_DEVICES_UPDATERename a device, edit its environment variables, or set its workflow, live sampling or production mode. Requires the ``device:update`` scope. For runtime configuration (streams, services, versions) use ``devices_update_config``.
Devices update config
ROBOFLOW_MCP_DEVICES_UPDATE_CONFIGUpdate the device's runtime configuration. Requires ``device:update``. Uses JSON Merge Patch, so a small nested change preserves sibling settings; null explicitly deletes a key. Set ``config.camera_stream_disabled`` to true to stop live camera viewing on this device, or set ``config.camera_stream_disabled_streams`` to an array of stream names to stop viewing only those streams. The list is on ``config``, not inside ``config.stream.<name>``; arrays replace the whole list. Pending opt-outs restrict viewing immediately, including changes awaiting production approval or a maintenance window. A queued re-enable does not lift an active restriction until applied. Workspace-wide viewing is controlled in the session-authenticated web setting; its ``/query/workspace/updateCameraStreamDisabled`` route is unavailable to MCP credentials. Deployment-affecting changes wait for the next maintenance window when one is configured and not currently active. Schedule, timezone, and device name/type changes can apply immediately when approval is not required. Returns ``{success, staged: true, configProposal}`` when a production change awaits approval. This does not change live config. Otherwise returns ``{success, config, deferred}``; check ``deferred`` and ``config.pendingUpdates`` before claiming the change is live. Unapproved changes stay held through maintenance windows. MCP cannot approve a proposal. ``force_apply`` and ``immediate_delta`` are query-only controls, not fields in the config payload. Enabling Vision Events backup additionally requires the platform's ``vision-events:write`` scope. On supported edge releases, an uploaded workspace Asset Library video can be used directly: set config.stream.<stream-name>.video_reference to asset://<finalVideoId>, alongside its workflow_id and workspace_name. Do not put an asset reference in config.video_sources or use a signed download URL as the stream reference. The caller needs image:read and access to the uploaded video; the device API key also needs image:read and access to its folder. For nearby-claimed runtime keys, use the RTSP Simulator. Direct playback needs network access for its first download, enough disk space, and a video within the device cache limit (1 GiB by default, set by ASSET_VIDEO_CACHE_MAX_BYTES). Check staged, deferred, and pendingUpdates before treating the stream as active. The RTSP Simulator remains an option. For either path, call video_upload without project_id, PUT the bytes, and poll video_upload_status until "uploaded". Use the final videoId from that status response, which may differ after deduplication. For the simulator path, read the effective device config with devices_get_config before patching. Select an existing RTSP Simulator service or add one under services.<name>. For a new service, choose free host RTSP and web ports across published ports and service *PORT environment variables, including resolved $refs. Use the approved versioned simulator image tag in config.version.<name>, and set the service tag to {"$ref":"#/config/version/<name>"}; do not guess a tag. Use the image repo.roboflow.com/roboflow-edge/rtsp-simulator, restart="unless-stopped", and the persistent volume /var/lib/rfdm/rtsp-simulator/data:/data. Set RTSP_PORT and WEB_PORT to the selected ports and give it ROBOFLOW_API_KEY and API_BASE_URL environment variables as references to #/roboflow_api_key and #/api_base_url. Set RTSP_SIMULATOR_CONFIG to a JSON string with source="asset_library", the workspace slug, the final video_id, and upload_settings and stream_settings. For example the simulator defaults are target_fps=null, crf_quality=23, max_width=null, max_bitrate_kbps=5000, buffer_size_kb=3000, max_delay_ms=500. In the same config patch, set config.stream.<stream-name>.video_reference to rtsp://127.0.0.1:<host-RTSP-port>/stream, with its workflow_id and workspace_name. Loopback works only when inference uses host networking. Check staged, deferred, and pendingUpdates before treating the stream as active. New or changed ``config.kiosk.outputs`` selections require the workspace display controls feature and a fresh report from that device showing a connected, configurable connector. An explicit mode id must be selectable in that report; ``auto`` also requires a fresh compatible report. Removing an existing connector override with null returns it to automatic mode and remains possible without the feature or a fresh report. MCP cannot read the display report because its endpoint requires a Firebase session cookie. Choose a connector and mode from the current report in Device Manager.
Devices update default config
ROBOFLOW_MCP_DEVICES_UPDATE_DEFAULT_CONFIGReplace the workspace default device config patch. Requires the ``device:update`` scope. The merged result is validated against the RFDM config schema (400 with ``details`` on failure). New devices start from this config except display mode selections. The workspace default patch may retain or remove existing ``config.kiosk.outputs`` selections, but cannot add or change them. Choose display modes on each device after it reports its monitors.
Folders list
ROBOFLOW_MCP_FOLDERS_LISTList the workspace folders visible to this credential. Returns ``{ folders: [{id, name, parent_id, child_ids, projects, external_id}, ...] }``. ``projects`` holds the URLs of the projects in the folder; ``parent_id`` and ``child_ids`` describe the folder tree. ``child_ids`` names only folders this credential can list, but ``parent_id`` is the platform's value, so the top of a folder-scoped credential's subtree can point at a folder that is not in the list. A folder-scoped credential sees only its own folders. An empty list means no folders are visible to this credential, not necessarily that the workspace has none. Pass ``folder_id`` to fetch a single folder; an unknown id also yields an empty list.